{"id":1349,"date":"2022-10-06T00:00:00","date_gmt":"2022-10-06T00:00:00","guid":{"rendered":"https:\/\/ylu6kzueag.wpdns.site\/news\/power-transmission-line\/"},"modified":"2022-10-06T00:00:00","modified_gmt":"2022-10-06T00:00:00","slug":"ubertragungsleitung","status":"publish","type":"post","link":"https:\/\/www.yojiuelec.com\/de\/news\/power-transmission-line\/","title":{"rendered":"Grundkenntnisse \u00fcber \u00dcbertragungsleitungen"},"content":{"rendered":"<p><img alt=\"\u5c01\u9762\" decoding=\"async\" height=\"376\" loading=\"lazy\" src=\"\/assets\/article-restoration\/524404cbec5837ecd07f7f15.webp\" width=\"600\"\/><\/p>\n<p>\u4e00\u3001 Main equipment of power transmission line:<\/p>\n<p>The power transmission line is a power facility that uses insulators and corresponding hardware to suspend conductors and overhead<\/p>\n<p>ground wires on poles and towers, connect power plants and substations, and achieve the purpose of power transmission. It is mainly<\/p>\n<p>composed of conductor, overhead ground wire, insulator, hardware, tower, foundation, grounding device, etc.<\/p>\n<p>1. Conductor: its function is mainly to transmit electric energy. The line conductor shall have good conductivity, sufficient mechanical<\/p>\n<p>strength, vibration fatigue resistance and resistance to corrosion of chemical impurities in the air. It shall be a bundled conductor type<\/p>\n<p>composed of two or four conductors per phase.<\/p>\n<p>2. Overhead ground wire: mainly used for lightning protection. Due to the shielding of overhead ground wire to the conductor and the<\/p>\n<p>coupling between the conductor and overhead ground wire, the chance of lightning directly striking the conductor can be reduced. When<\/p>\n<p>lightning strikes the tower, part of the lightning current can be diverted through the overhead ground wire, thus reducing the tower top<\/p>\n<p>potential and improving the lightning withstand level. The overhead ground wire is usually galvanized steel strand. At present, good<\/p>\n<p>conductors such as steel cored aluminum strand and aluminum clad steel strand are often used to reduce power frequency overvoltage<\/p>\n<p>and secondary arc current in case of asymmetric short circuit. Optical cable composite overhead ground wire shall be used for those with<\/p>\n<p>communication function.<\/p>\n<p>3. Insulator: It refers to the object that fixes and suspends the conductor on the tower. Common insulators for power transmission lines<\/p>\n<p>include: disc porcelain insulator, disc glass insulator and rod suspension composite insulator.<\/p>\n<p>(1) Disc porcelain insulator: domestic porcelain insulator has a high deterioration rate, which requires zero value detection and heavy<\/p>\n<p>maintenance. In the event of lightning strike and pollution flashover, it is easy to cause string dropping accidents, which has been phased out.<\/p>\n<p>(2) Disc glass insulator: It has zero value self explosion, but the self explosion rate is very low (usually several ten thousandths). No inspection<\/p>\n<p>is required for maintenance. In case of self explosion of tempered glass, its residual mechanical strength still reaches more than 80% of the<\/p>\n<p>breaking force, and the safe operation of the line can still be ensured. In the event of lightning strike and pollution flashover, there will be no<\/p>\n<p>chain drop accident. It has been widely used in Grade I and II sewage areas.<\/p>\n<p>(3) Rod suspension composite insulator: it has the advantages of good anti pollution flashover performance, light weight, high mechanical<\/p>\n<p>strength, less maintenance, etc., and has been widely used in Grade III and above pollution areas.<\/p>\n<p>4. Hardware<\/p>\n<p>Power transmission line fittings can be divided into: clamp type, connection fittings, connection fittings, protective fittings and pull wire<\/p>\n<p>fittings according to their main performance and use.<\/p>\n<p>(1) Clamp type: suspension clamp: used to fix the conductor on the suspension insulator string of the tangent pole and tower, or hang the<\/p>\n<p>overhead ground wire on the overhead ground wire support of the tangent pole and tower.<\/p>\n<p>Strain clamp: it is used to fix the conductor or overhead ground wire on the strain insulator string for anchoring. There are three categories<\/p>\n<p>of strain clamps, namely: bolt type strain clamps; Compression type strain clamp; Wedge clamp. Bolt type strain clamp: it is used to fix the<\/p>\n<p>conductor by the friction effect generated by the vertical pressure of U-shaped screw and the wavy groove of the clamp. Compression type<\/p>\n<p>tension clamp: it is composed of aluminum tube and steel anchor. The steel anchor is used to connect and anchor the steel core of the steel<\/p>\n<p>cored aluminum strand, and then cover the aluminum tube body to make the metal plastic deformation by pressure, so that the wire clamp<\/p>\n<p>and the conductor are combined as a whole. When hydraulic pressure is used, the steel mold with corresponding specifications shall be used<\/p>\n<p>for compression with a hydraulic press. When explosive pressure is used, the wire clamp and conductor (overhead ground wire) can be<\/p>\n<p>pressed into a whole by means of primary explosive pressure or secondary explosive pressure.<\/p>\n<p>Wedge clamp: used to install steel strand and fasten the stay wire of overhead ground wire and stay tower. It uses the splitting force of wedge<\/p>\n<p>to lock the steel strand in the clamp.<\/p>\n<p>(2) Connecting hardware: connecting hardware is used to connect insulator string and tower, wire clamp and insulator string, overhead ground<\/p>\n<p>wire clamp and tower. Commonly used connection hardware includes ball head hanging ring, bowl head hanging plate, U-shaped hanging ring,<\/p>\n<p>right angle hanging plate, etc.<\/p>\n<p>(3) Connection fittings: used for the connection of conductors, overhead ground wires and jumpers of tension poles and towers. The finalized<\/p>\n<p>connection fittings include: clamp pressure connection fittings, hydraulic connection fittings, bolt connection fittings, explosive pressure<\/p>\n<p>connection fittings.<\/p>\n<p>(4) Protective hardware: shockproof hammer, armour rod and damping wire used to protect conductor and overhead ground wire from vibration;<\/p>\n<p>Spacer used to suppress subspan vibration; Shielding ring and grading ring used to protect insulator string from corona.<\/p>\n<p>(5) Hardware for stay wire: hardware for adjusting and stabilizing tower stay wire include: adjustable UT type clamp; Steel wire clamp, and double<\/p>\n<p>pulling wire connecting plate, etc.<\/p>\n<p>5. Tower:<\/p>\n<p>Towers are used to support overhead line conductors and overhead ground wires, and to ensure that there is sufficient safety distance between<\/p>\n<p>conductors and conductors, between conductors and overhead ground wires, between conductors and towers, and between conductors and the<\/p>\n<p>earth and crossing objects.<\/p>\n<p>6. Foundation:<\/p>\n<p>The foundation is mainly used to stabilize the tower and can bear the uplift force, downforce and overturning moment generated by various loads<\/p>\n<p>of tower, conductor and overhead ground wire.<\/p>\n<p>Prefabricated fabricated foundation shall be used for poles and stay wires. Cast in situ reinforced concrete foundation or concrete foundation should<\/p>\n<p>be used for iron tower. If possible, the undisturbed foundation shall be preferred. Including: rock foundation, mechanically expanded pile foundation,<\/p>\n<p>cut (half cut) foundation, explosive expanded pile foundation and bored pile foundation.<\/p>\n<p>7. Grounding device:<\/p>\n<p>It is mainly composed of the grounding downlead connecting the overhead ground wire and the grounding body (pole) buried in the tower ground.<\/p>\n<p>The main function of the grounding device is to rapidly diffuse and discharge the lightning current in the earth, so as to maintain a certain lightning<\/p>\n<p>withstand level of the line. The smaller the grounding resistance of tower, the higher the lightning withstand level.<\/p>\n<p>\u4e8c\u3001 Terminology of power transmission lines<\/p>\n<p>1. Span: the horizontal straight distance between two adjacent towers, called span, is generally expressed in L.<\/p>\n<p>2. Sag: for horizontally erected lines, the vertical distance between the horizontal connecting line between two adjacent suspension points of the<\/p>\n<p>conductor and the lowest point of the conductor is called sag or sag. Expressed by f.<\/p>\n<p>3. Distance limit: the minimum distance between the conductor and the ground or the crossed facilities. The minimum allowable distance from the<\/p>\n<p>lowest point of the general guidance line to the ground, usually expressed in h.<\/p>\n<p>4. Horizontal span: half of the sum of two adjacent spans is called horizontal span, which is commonly expressed as.<\/p>\n<p>5. Vertical span: the horizontal distance between the lowest points of the conductor between two adjacent spans, which is called vertical span and<\/p>\n<p>is usually expressed.<\/p>\n<p>6. Representative span: in a tension section, there are often multiple spans except for arc vertical spans. Due to different terrain and ground objects<\/p>\n<p>crossed by the conductor, the size of each span is not equal, the elevation of the suspension point of the conductor is also different, and the stress of<\/p>\n<p>the conductor in each span is also different. However, the stress and sag of the conductor are closely related to the span. When the span changes, the<\/p>\n<p>stress and sag of the conductor also change. If each span is calculated one by one, the mechanical calculation of the conductor will be difficult. However,<\/p>\n<p>the conductors of the same phase in a tension section are tightened together during construction. Therefore, the horizontal tension of the conductor is<\/p>\n<p>equal in the whole tension section, that is, the conductor stress at the lowest point of the sag of each span is equal. We replace a multi span tension<\/p>\n<p>section with an equivalent imaginary span. This imaginary span that can express the whole mechanical law of tension is called representative span or<\/p>\n<p>regular span, and is represented by LO.<\/p>\n<p>7. Tower height: the vertical distance from the highest point of the tower to the ground, called tower height. It is indicated by H1.<\/p>\n<p>8. Tower nominal height: the vertical distance from the lowest cross arm of the tower to the ground is called tower nominal height, which is referred<\/p>\n<p>to as nominal height and is expressed in H2.<\/p>\n<p>9. Height of suspension point: the vertical distance from the suspension point of the conductor to the ground, which is called the height of the suspension<\/p>\n<p>point of the conductor and is represented by H3.<\/p>\n<p>10. Line to line distance: the horizontal distance between two phases of conductors, called line to line distance, expressed in D.<\/p>\n<p>11. Root opening: the horizontal distance between the roots or tower feet of two electric poles, called root opening. It is represented by A.<\/p>\n<p>12. Protection angle of overhead ground wire: the included angle between the external connecting line of overhead ground wire and side conductor and<\/p>\n<p>the vertical line of overhead ground wire is called the protection angle of overhead ground wire. Expressed in.<\/p>\n<p>13. Burial depth of pole and tower: The depth of the electric pole (tower base) buried in the soil is called the buried depth of the pole and tower. It is<\/p>\n<p>expressed in h0.<\/p>\n<p>14. Jumper: the lead connecting the conductors on both sides of the load-bearing tower (tension, corner and terminal tower) is called jumper, also<\/p>\n<p>called drain wire or bow wire.<\/p>\n<p>15. Initial elongation of conductor: permanent deformation (stretching along the axis of conductor) caused by the initial external tension of conductor<\/p>\n<p>is called initial elongation of conductor.<\/p>\n<p>16. Bundled conductor: one phase conductor is composed of multiple wires (2, 3, 4), which is called bundled conductor. It is equivalent to thickening<\/p>\n<p>the \u201cequivalent diameter\u201d of the conductor, improving the electric field strength near the conductor, reducing corona loss, reducing radio interference,<\/p>\n<p>and improving the transmission capacity of the transmission line.<\/p>\n<p>17. Conductor transposition: the conductor arrangement of the power transmission line, except for the regular triangle arrangement, the distance<\/p>\n<p>between the three conductors is not equal. The reactance of the conductor depends on the distance between lines and the radius of the conductor.<\/p>\n<p>Therefore, if the conductor is not transposed, the three-phase impedance is unbalanced. The longer the line is, the more serious the imbalance is.<\/p>\n<p>As a result, unbalanced voltage and current will be generated, which will adversely affect the operation of the generator and radio communication.<\/p>\n<p>The power transmission line design specification stipulates that \u201cin the power network with the neutral point directly grounded, the power transmission<\/p>\n<p>line with a length of more than 100km shall be transposed\u201d. Conductor transposition is generally carried out in transposition tower.<\/p>\n<p>18. Conductor (ground) line vibration: in the line span, when overhead lines are subjected to the wind force perpendicular to the line direction,a stable<\/p>\n<p>vortex with a certain frequency alternating up and down will be formed on the leeward side of overhead lines. Under the effect of the vortex lift<\/p>\n<p>component, the overhead lines will produce periodic oscillation in their vertical plane, which is called overhead line vibration.<\/p>\n<p>\u00a0<\/p>\n<div><\/div>","protected":false},"excerpt":{"rendered":"<p>1. Hauptausr\u00fcstung von \u00dcbertragungsleitungen: Die \u00dcbertragungsleitung ist eine elektrische Anlage, die Isolatoren und zugeh\u00f6rige Befestigungsteile verwendet, um Leiterseile und Erdseile an Masten und T\u00fcrmen aufzuh\u00e4ngen sowie Kraftwerke und Umspannstationen zu verbinden.<\/p>","protected":false},"author":1,"featured_media":1268,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[26],"tags":[],"class_list":["post-1349","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news"],"_links":{"self":[{"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/posts\/1349","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/comments?post=1349"}],"version-history":[{"count":0,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/posts\/1349\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/media\/1268"}],"wp:attachment":[{"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/media?parent=1349"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/categories?post=1349"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/tags?post=1349"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}