{"id":1496,"date":"2023-02-28T00:00:00","date_gmt":"2023-02-28T00:00:00","guid":{"rendered":"https:\/\/ylu6kzueag.wpdns.site\/news\/key-points-for-internal-lightning-protection-of-wind-turbine-generator\/"},"modified":"2023-02-28T00:00:00","modified_gmt":"2023-02-28T00:00:00","slug":"key-points-for-internal-lightning-protection-of-wind-turbine-generator","status":"publish","type":"post","link":"https:\/\/www.yojiuelec.com\/de\/news\/key-points-for-internal-lightning-protection-of-wind-turbine-generator\/","title":{"rendered":"Key points for internal lightning protection of wind turbine generator"},"content":{"rendered":"<p>1. Damage of lightning to wind turbine generator;<\/p>\n<p>2. Damage form of lightning;<\/p>\n<p>3. Internal lightning protection measures;<\/p>\n<p>4. Lightning protection equipotential connection;<\/p>\n<p>5. Shielding measures;<\/p>\n<p>6. Surge protection.<\/p>\n<p>\u00a0<\/p>\n<p>With the increase of the capacity of wind turbines and the scale of wind farms, the safe operation of wind farms has become increasingly important.<\/p>\n<p>Among many factors that affect the safe operation of wind farms, lightning strike is an important aspect. Based on the research results of lightning<\/p>\n<p>protection for wind turbines, this paper describes the lightning process, damage mechanism and lightning protection measures of wind turbines.<\/p>\n<p>\u00a0<\/p>\n<p><a href=\"\/de\/assets\/article-restoration\/00f0ac9f7297393875ee7c82.jpg\/\"><img alt=\"Wind power\" decoding=\"async\" height=\"531\" loading=\"lazy\" src=\"\/assets\/article-restoration\/00f0ac9f7297393875ee7c82.jpg\" width=\"800\"\/><\/a><\/p>\n<p>\u00a0<\/p>\n<p>Due to the rapid development of modern science and technology, the single capacity of wind turbines is becoming larger and larger. In order to<\/p>\n<p>absorb more energy, the hub height and impeller diameter are increasing. The height and installation position of the wind turbine determine that<\/p>\n<p>it is the preferred channel for lightning strikes. In addition, a large number of sensitive electrical and electronic equipment are concentrated inside<\/p>\n<p>the wind turbine. The damage caused by a lightning strike will be very large. Therefore, a complete lightning protection system must be installed<\/p>\n<p>for the electrical and electronic equipment in the fan.<\/p>\n<p>\u00a0<\/p>\n<p>1. Damage of lightning to wind turbines<\/p>\n<p>\u00a0<\/p>\n<p>The hazard of lightning to wind turbine generator is usually located in an open area and very high, so the whole wind turbine is exposed to the threat<\/p>\n<p>of direct lightning strike, and the probability of being directly hit by lightning is proportional to the square value of the height of the object. The blade<\/p>\n<p>height of the megawatt wind turbine reaches more than 150m, so the blade part of the wind turbine is particularly vulnerable to lightning. A large<\/p>\n<p>number of electrical and electronic equipment are integrated inside the fan. It can be said that almost every kind of electronic components and electrical<\/p>\n<p>equipment we normally use can be found in a wind turbine generator set, such as switch cabinet, motor, drive device, frequency converter, sensor,<\/p>\n<p>actuator, and corresponding bus system. These devices are concentrated in a small area. There is no doubt that power surges can cause considerable<\/p>\n<p>damage to wind turbines.<\/p>\n<p>\u00a0<\/p>\n<p>The following data of wind turbines are provided by several European countries, including data of more than 4000 wind turbines. Table 1 is a summary<\/p>\n<p>of these accidents in Germany, Denmark and Sweden. The number of wind turbine damage caused by lightning strikes is 3.9 to 8 times per 100 units per<\/p>\n<p>year. According to statistical data, 4-8 wind turbines in Northern Europe are damaged by lightning every year for every 100 wind turbines. It is worth<\/p>\n<p>noting that although the damaged components are different, the lightning damage of control system components accounts for 40-50%.<\/p>\n<p>\u00a0<\/p>\n<p>2. Damage form of lightning<\/p>\n<p>\u00a0<\/p>\n<p>There are usually four cases of equipment damage caused by lightning stroke. First, the equipment is directly damaged by lightning stroke; The second is<\/p>\n<p>that the lightning pulse intrudes into the equipment along the signal line, power line or other metal pipelines connected with the equipment, causing<\/p>\n<p>damage to the equipment; The third is that the equipment grounding body is damaged due to the \u201ccounterattack\u201d of the ground potential caused<\/p>\n<p>by the\u00a0instantaneous high potential generated during the lightning stroke; Fourth, the equipment is damaged due to improper installation method<\/p>\n<p>or installation\u00a0position, and is affected by the electric field and magnetic field distributed by lightning in space.<\/p>\n<p>\u00a0<\/p>\n<p>3. Internal lightning protection measures<\/p>\n<p>\u00a0<\/p>\n<p>The concept of lightning protection zone is the basis for planning comprehensive lightning protection of wind turbines. It is a design method for structural<\/p>\n<p>space to create a stable electromagnetic compatibility environment in the structure. The anti-electromagnetic interference ability of different electrical<\/p>\n<p>equipment in the structure determines the requirements for this space electromagnetic environment.<\/p>\n<p>\u00a0<\/p>\n<p>As a protection measure, the concept of lightning protection zone of course includes that electromagnetic interference (conductive interference and<\/p>\n<p>radiation\u00a0interference) should be reduced to an acceptable range at the boundary of the lightning protection zone. Therefore, different parts of the<\/p>\n<p>protected structure\u00a0are subdivided into different lightning protection zones. The specific division of the lightning protection zone is related to the<\/p>\n<p>structure of the wind turbine,and the structural building form and materials should also be considered. By setting shielding devices and installing<\/p>\n<p>surge protectors, the impact of lightning\u00a0in Zone 0A of the lightning protection zone is greatly reduced when entering Zone 1, and the electrical and<\/p>\n<p>electronic equipment in the wind turbine can\u00a0work normally without interference.<\/p>\n<p>\u00a0<\/p>\n<p>The internal lightning protection system is composed of all facilities to reduce the lightning electromagnetic effect in the area. It mainly includes lightning<\/p>\n<p>protection equipotential connection, shielding measures and surge protection.<\/p>\n<p>\u00a0<\/p>\n<p>4. Lightning protection equipotential connection<\/p>\n<p>\u00a0<\/p>\n<p>Lightning protection equipotential connection is an important part of the internal lightning protection system. Equipotential bonding can effectively<\/p>\n<p>suppress the potential difference caused by lightning. In the lightning protection equipotential bonding system, all conductive parts are interconnected<\/p>\n<p>to reduce the\u00a0potential difference. In the design of equipotential bonding, the minimum connection cross-sectional area shall be considered according<\/p>\n<p>to the standard. A\u00a0complete equipotential connection network also includes equipotential connection of metal pipelines and power and signal lines,<\/p>\n<p>which shall be connected\u00a0to the main grounding busbar through lightning current protector.<\/p>\n<p>\u00a0<\/p>\n<p>5. Shielding measures<\/p>\n<p>\u00a0<\/p>\n<p>Shielding device can reduce electromagnetic interference. Due to the particularity of the wind turbine structure, if the shielding measures can be<\/p>\n<p>considered at the design stage, the shielding device can be realized at a lower cost. The engine room shall be made into a closed metal shell, and<\/p>\n<p>the relevant electrical and electronic components shall be installed in the switch cabinet. The cabinet body of the switch cabinet and control<\/p>\n<p>cabinet shall have good shielding effect. Cables between different equipment in tower base and engine room shall be provided with external metal<\/p>\n<p>shielding layer. For interference suppression, the shielding layer is effective only when both ends of the cable shield are connected to the<\/p>\n<p>equipotential bonding belt.<\/p>\n<p>\u00a0<\/p>\n<p>6. Surge protection<\/p>\n<p>\u00a0<\/p>\n<p>In addition to using shielding measures to suppress radiation interference sources, corresponding protective measures are also required for<\/p>\n<p>conductive interference at the boundary of lightning protection zone, so that electrical and electronic equipment can work reliably. Lightning<\/p>\n<p>arrester must be used at the boundary of lightning protection zone 0A \u2192 1, which can lead a large amount of lightning current without damaging<\/p>\n<p>the equipment. This type of lightning protector is also called lightning current protector (Class I lightning protector). They can limit the high<\/p>\n<p>potential difference caused by lightning between the grounded metal facilities and power and signal lines, and limit it to a safe range. The most<\/p>\n<p>important characteristic of lightning current protector is: according to 10\/350 \u03bc S pulse waveform test, can withstand lightning current. For<\/p>\n<p>wind turbines, lightning protection at the boundary of power line 0A \u2192 1 is completed at the 400\/690V power supply side.<\/p>\n<p>\u00a0<\/p>\n<p>In the lightning protection area and the subsequent lightning protection area, only pulse current with small energy exists. This kind of pulse current<\/p>\n<p>is generated by the external induced overvoltage or the surge generated from the system. The protection equipment for this kind of impulse current<\/p>\n<p>is called surge protector (Class II lightning protector). Use 8\/20 \u03bc S pulse current waveform. From the perspective of energy coordination, the surge<\/p>\n<p>protector needs to be installed downstream of the lightning current protector.<\/p>\n<p>\u00a0<\/p>\n<p>Considering the current flow, for example, for a telephone line, the lightning current on the conductor should be estimated at 5%. For Class III\/IV<\/p>\n<p>lightning protection system, it is 5kA (10\/350 \u03bc s)\u3002<\/p>\n<p>\u00a0<\/p>\n<p>7. Conclusion<\/p>\n<p>\u00a0<\/p>\n<p>The lightning energy is very huge, and the lightning strike mode is complex. Reasonable and appropriate lightning protection measures can only reduce<\/p>\n<p>the loss. Only the breakthrough and application of more new technologies can fully protect and utilize the lightning. The lightning protection scheme<\/p>\n<p>analysis and discussion of wind power system should mainly consider the grounding system design of wind power. Since wind power in China is<\/p>\n<p>involved in various geological landforms, the grounding system of wind power in different geology can be designed by classification, and different<\/p>\n<p>methods can be adopted to meet the grounding resistance requirements.<\/p>\n<p>\u00a0<\/p>\n<div><\/div>","protected":false},"excerpt":{"rendered":"<p>1. Damage of lightning to wind turbine generator; 2. Damage form of lightning; 3. Internal lightning protection measures; 4. Lightning protection equipotential connection; 5. Shielding measures; 6. Surge protection. With the increase of the<\/p>","protected":false},"author":1,"featured_media":1238,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[26],"tags":[],"class_list":["post-1496","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news"],"_links":{"self":[{"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/posts\/1496","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/comments?post=1496"}],"version-history":[{"count":0,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/posts\/1496\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/media\/1238"}],"wp:attachment":[{"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/media?parent=1496"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/categories?post=1496"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/tags?post=1496"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}