{"id":278,"date":"2023-10-16T00:00:00","date_gmt":"2023-10-16T00:00:00","guid":{"rendered":"https:\/\/ylu6kzueag.wpdns.site\/news\/ground-wire-wedge-clamps-and-pre-twisted-clamps\/"},"modified":"2023-10-16T00:00:00","modified_gmt":"2023-10-16T00:00:00","slug":"ground-wire-wedge-clamps-and-pre-twisted-clamps","status":"publish","type":"post","link":"https:\/\/www.yojiuelec.com\/de\/news\/ground-wire-wedge-clamps-and-pre-twisted-clamps\/","title":{"rendered":"Ground wire wedge clamps and pre-twisted clamps"},"content":{"rendered":"<p class=\"article-dek\">Among the types of clamps used in high-voltage overhead lines, straight boat-type clamps and crimped tension-resistant tube-type <\/p>\n<p>tension clamps are more common. There are also pre-twisted clamps and wedge-type clamps. Wedge-type clamps are known for <\/p>\n<p>their simplicity. The structure and installation method are recommended by many installation and operation departments. The <\/p>\n<p>pre-twisted cable clamp is the standard cable clamp of OPGW. It is now also called the common backup cable clamp type in the <\/p>\n<p>\u201cthree-span\u201d section. Today, let\u2019s take a look at these two The structure and precautions of the seed clamp.<\/p>\n<h2 id=\"section-1\"><strong>1 wedge clamp<\/strong><\/h2>\n<p>1.1 Usage of wedge clamp<\/p>\n<p> Wedge-type cable clamps can replace common compression and tension-resistant cable clamps, and can also be used as backup<\/p>\n<p> cable clamps, which can be used for ground wires and conductors. Due to structural characteristics, wedge clamps are only used<\/p>\n<p> in tension towers.<\/p>\n<p>1.2 Wedge clamp structure<\/p>\n<p> There is a wedge in the wedge clamp cavity. When the conductor and the clamp are relatively displaced, the conductor, the wedge, <\/p>\n<p>and the clamp cavity are automatically compressed to ensure the clamp\u2019s grip on the conductor. Its structure is shown in Figure 1.<\/p>\n<p><a href=\"https:\/\/www.yojiuelec.com\/de\/uploads\/113.png\/\"><img alt=\"11\" decoding=\"async\" height=\"274\" loading=\"lazy\" src=\"https:\/\/www.yojiuelec.com\/wp-content\/uploads\/yojiu\/blog-20261112\/af71bf8ba39a7924.webp\" width=\"472\"\/><\/a><\/p>\n<p>Figure 1 Wedge clamp structure<\/p>\n<p>In Figure 1, 1 is the cable clamp cavity, 3 and 4 are wedges, used to compress the ground wire, and the lower wedge 3 has a tail<\/p>\n<p> leading out. For conventional wedge-type cable clamps, jumpers can be installed here. Wedge-type backup cable clamp, since there<\/p>\n<p> is no need to connect jumpers, there may be no lead-out device here. The disassembly of a wedge-type cable clamp is shown in <\/p>\n<p>Figure 2, and the on-site installation diagram is shown in Figure 3.<\/p>\n<p><a href=\"https:\/\/www.yojiuelec.com\/de\/uploads\/\u56fe21.jpeg\/\"><img alt=\"Figure 2 Disassembly of wedge clamp\" decoding=\"async\" height=\"362\" loading=\"lazy\" src=\"https:\/\/www.yojiuelec.com\/wp-content\/uploads\/yojiu\/blog-20261112\/efcf0a9c2334d0b3.jpg\" width=\"674\"\/><\/a><\/p>\n<p>Figure 2 Disassembly of wedge clamp<\/p>\n<p><a href=\"https:\/\/www.yojiuelec.com\/de\/uploads\/Figure-3-Wedding-wire-clip-backup-line-clip-on-site-installation-map.jpeg\/\"><img alt=\"Figure 3 Wedding wire clip (backup line clip) on -site installation map\" decoding=\"async\" height=\"600\" loading=\"lazy\" src=\"https:\/\/www.yojiuelec.com\/wp-content\/uploads\/yojiu\/blog-20261112\/e9a54ff6c433d6ef.jpg\" width=\"800\"\/><\/a><\/p>\n<p>Figure 3 Wedding wire clip (backup line clip) on -site installation map<\/p>\n<p>2.3 Precautions for wedge-type cable clamps<\/p>\n<p>1) Installation pre-tightening force of wedge-type backup cable clamp<\/p>\n<p>The wedge of the wedge clamp cannot move in the tightening direction, but can move in the opposite direction. If the wedge clamp and<\/p>\n<p> the ground wire are not tightened, the wedge will be slowly sent out under the action of long-term wind vibration. Therefore, pre-tightening<\/p>\n<p> force must be applied when installing the wedge backup cable clamp, and necessary anti-loosening measures must be taken.<\/p>\n<p>2) The position of the anti-vibration hammer after installing the wedge clamp<\/p>\n<p>After the wedge clamp is installed, its fracture will inevitably become a fixed point, so the installation distance of the anti-vibration hammer<\/p>\n<p> should be calculated from the exit of the wedge clamp cavity.<br \/>\n2 pre-twisted wire clips<\/p>\n<p>2.1 Application of pre-twisted wire clamps<\/p>\n<p> OPGW contains communication optical fibers. General crimp-type tension-resistant cable clamps can easily damage the internal optical fiber<\/p>\n<p> during the crimping process. Pre-twisted cable clamps do not have such problems. Therefore, pre-twisted cable clamps were first used in OPGW,<\/p>\n<p> including straight wires. Clamps and tension clamps. With the development of technology, it is gradually used in general lines. In recent years, <\/p>\n<p>the operation department\u2019s attention to three-span has opened up a new use of pre-twisted cable clamps \u2013 as backup cable clamps (safety <\/p>\n<p>backup cable clamps) for three-span sections.<\/p>\n<p>2.2 Pre-twisted cable clamp structure<\/p>\n<p>1) Ground wire pre-twisted backup clamp<\/p>\n<p>The purpose of the ground wire backup clamp is to use the backup clamp to provide gripping force to the ground wire when the original tension<\/p>\n<p> clamp outlet of the ground wire is broken (operational statistics show that most of the ground wire breakage occurs at the wire clamp outlet). <\/p>\n<p>Reliably connect with wires to avoid ground wire falling accidents.<\/p>\n<p>The appearance and structure of the pre-twisted backup cable clamp are shown in Figure 4 and Figure 5. The pre-twisted wire forms an <\/p>\n<p>empty tube, and the inner surface contains sand. During installation, the pre-twisted wire is wrapped around the ground wire, and the pre-twisted<\/p>\n<p> wire compression force and the inner surface are used. The grit on the surface provides grip. According to the size of the on-site ground wire, <\/p>\n<p>the pre-twisted wire of the backup clamp can be divided into 2 layers and 1 layer. The 2-layer structure means that a layer of pre-twisted wire is <\/p>\n<p>installed outside the ground wire, and then a pre-twisted wire with a ring is installed in addition to the pre-twisted wire. The twisted wire clamp has<\/p>\n<p> sand in both layers of pre-twisted wire.<\/p>\n<p><a href=\"https:\/\/www.yojiuelec.com\/de\/uploads\/Figure-4-Appearance-of-pre-twisted-cable-clamp.jpeg\/\"><img alt=\"Figure 4 Appearance of pre-twisted cable clamp\" decoding=\"async\" height=\"79\" loading=\"lazy\" src=\"https:\/\/www.yojiuelec.com\/wp-content\/uploads\/yojiu\/blog-20261112\/2c2fdf2bc5d98151.jpg\" width=\"491\"\/><\/a><\/p>\n<p>Figure 4 Appearance of pre-twisted cable clamp<\/p>\n<p><a href=\"https:\/\/www.yojiuelec.com\/de\/uploads\/Figure-5-Simple-installation-diagram-of-pre-twisted-cable-clamp.png\/\"><img alt=\"Figure-5-Simple-installation-diagram-of-pre-twisted-cable-clamp\" decoding=\"async\" height=\"247\" loading=\"lazy\" src=\"https:\/\/www.yojiuelec.com\/wp-content\/uploads\/yojiu\/blog-20261112\/b3de2d2d5d3af72e.webp\" width=\"554\"\/><\/a><\/p>\n<p>Figure 5 Simple installation diagram of pre-twisted cable clamp<\/p>\n<p>2) Pre-twisted OPGW cable clamp<\/p>\n<p>For OPGW, pre-twisted cable clamps are components that bear mechanical tension and can be divided into two types: tensile and straight. <\/p>\n<p>The tensile on-site installation is shown in Figure 6, and the straight on-site installation is shown in Figure 7.<\/p>\n<p><a href=\"https:\/\/www.yojiuelec.com\/de\/uploads\/Figure-6-OPGW-tension-resistant-pre-twisted-cable-clamp.jpeg\/\"><img alt=\"Figure 6 OPGW tension-resistant pre-twisted cable clamp\" decoding=\"async\" height=\"608\" loading=\"lazy\" src=\"https:\/\/www.yojiuelec.com\/wp-content\/uploads\/yojiu\/blog-20261112\/79bd5d2feb72fbd7.jpg\" width=\"1080\"\/><\/a><\/p>\n<p>Figure 6 OPGW tension-resistant pre-twisted cable clamp<\/p>\n<p>The main structure of the OPGW tensile-resistant pre-twisted cable clamp is the same as the above-mentioned ground wire pre-twisted <\/p>\n<p>backup cable clamp. The pre-twisted wire and internal sand are in close contact with the OPGW to provide gripping force. It should be <\/p>\n<p>noted that the OPGW tensile-resistant pre-twisted cable clamp The clips all have a 2-layer pre-twisted wire structure. The inner layer of<\/p>\n<p> pre-twisted wire provides protection for the OPGW on the one hand, and on the other hand, the outer layer of pre-twisted wire changes<\/p>\n<p> the shape significantly and ensures sufficient grip strength. In addition, for pole towers that need to be grounded, some pre-twisted tension <\/p>\n<p>clamps are equipped with special drainage wires to ensure that the OPGW is well grounded.<\/p>\n<p><a href=\"https:\/\/www.yojiuelec.com\/de\/uploads\/Figure-7-OPGW-linear-pre-twisted-cable-clamp.jpeg\/\"><img alt=\"Figure 7 OPGW linear pre-twisted cable clamp\" decoding=\"async\" height=\"608\" loading=\"lazy\" src=\"https:\/\/www.yojiuelec.com\/wp-content\/uploads\/yojiu\/blog-20261112\/912d7a20dc175528.jpg\" width=\"1080\"\/><\/a><\/p>\n<p>Figure 7 OPGW linear pre-twisted cable clamp<\/p>\n<p>There are two differences between the OPGW linear pre-twisted cable clamp and the tensile strength. First, there is generally no sand <\/p>\n<p>inside the linear pre-twisted cable clamp, because the linear tower does not need to withstand the tensile force of the wire; the second <\/p>\n<p>is the connection between the cable clamp and the tower body. The structure is different and is connected to the tower body through <\/p>\n<p>special expansion protection and hardware.<\/p>\n<p>3) Pre-twisted wire backup clamp<\/p>\n<p>When defects in the original tension clamp occur in the conductor, the pre-twisted backup clamp can be used as a temporary treatment <\/p>\n<p>measure to provide sufficient holding force and flow capacity. The structure is shown in Figure 8.<\/p>\n<p><a href=\"https:\/\/www.yojiuelec.com\/de\/uploads\/Figure-8-Pre-twisted-wire-backup-clamp.png\/\"><img alt=\"Figure-8-Pre-twisted-wire-backup-clamp\" decoding=\"async\" height=\"321\" loading=\"lazy\" src=\"https:\/\/www.yojiuelec.com\/wp-content\/uploads\/yojiu\/blog-20261112\/771df6aa8c1201e2.webp\" width=\"669\"\/><\/a><\/p>\n<p>Figure 8 Pre-twisted wire backup clamp<\/p>\n<p>In Figure 8, the pre-twisted wires 2 and 3 are used to connect to the adjustment plate to provide mechanical support, and the drainage<\/p>\n<p> wire 7 is used to connect the wire and the original drainage jumper to achieve flow, thereby avoiding overheating and other defects due<\/p>\n<p> to the position of the tension clamp drainage plate. Affects the flow of wires.<\/p>\n<p>2.3 Precautions for pre-twisted cable clamps<\/p>\n<p>1) The grounding method and internal sand material of the pre-twisted backup cable clamp<\/p>\n<p>There are two types of sand grains inside the pre-twisted wire. One is non-conductive emery. The ground wire-pre-twisted wire interface<\/p>\n<p> formed by the pre-twisted wire clip has relatively poor electrical conductivity and is generally not used in areas where flow may occur. <\/p>\n<p>Another type of sand is conductive sand doped with metal, which has a certain degree of conductivity and is used in working conditions<\/p>\n<p> where flow may occur.<\/p>\n<p>For lines where the ground wire is insulated from tower to tower, in order not to change the original grounding method, the backup wire<\/p>\n<p> clamp is insulated (such as a backup wire clamp with a piece of insulator strung together). The amplitude of the induced current in the <\/p>\n<p>ground wire is very low at ordinary times. When a lightning counterattack occurs, it is generally The lightning energy is discharged through <\/p>\n<p>the gap of the ground wire insulator. At this time, the backup clamp will not bear the flow function, so the sand inside the clamp can be <\/p>\n<p>made of emery.<\/p>\n<p>For lines where ground wires are grounded from tower to tower, the backup wire clips are generally directly grounded to the tower body<\/p>\n<p> through fittings. Normally, the induced current in the line is large, and when a lightning counterattack occurs, current will pass through<\/p>\n<p> the backup wire clips. At this time, conductive wire clamps should be used in the backup wire clips. sand.<\/p>\n<p>For lines with a single-end grounding in the ground wire tension section, the grounding method of the pre-twisted backup clamp is the <\/p>\n<p>same as the grounding method of the original ground wire at the tower location. At the same time, if it is insulated, emery can be used. <\/p>\n<p>The internal part of the directly grounded backup clamp should be Use conductive sand. This is also the grounding method and sand <\/p>\n<p>selection principle of the pre-twisted backup cable clamp.<\/p>\n<p>2) The material combination of the pre-twisted cable clamp and the ground wire<\/p>\n<p>The pre-twisted cable clamp is equivalent to adding a layer of metal protective strip outside the ground wire. If the materials between<\/p>\n<p> the two are not matched well, it will cause electrochemical corrosion problems when the conductivity of rainwater is high. Therefore,<\/p>\n<p> the same material as the ground wire is generally selected as the material of the pre-twisted cable clamp.<\/p>\n<p>3) End treatment of pre-twisted wire<\/p>\n<p>The tail end of the pre-twisted wire should be rounded to avoid corona, and at the same time, the pre-twisted wire should be prevented <\/p>\n<p>from rising and causing poor contact with the ground wire.<\/p>\n<div><\/div>","protected":false},"excerpt":{"rendered":"<p>Among the types of clamps used in high-voltage overhead lines, straight boat-type clamps and crimped tension-resistant tube-type<\/p>","protected":false},"author":1,"featured_media":264,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[27],"tags":[],"class_list":["post-278","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/posts\/278","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/comments?post=278"}],"version-history":[{"count":0,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/posts\/278\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/media\/264"}],"wp:attachment":[{"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/media?parent=278"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/categories?post=278"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/de\/wp-json\/wp\/v2\/tags?post=278"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}