{"id":1302,"date":"2022-11-05T00:00:00","date_gmt":"2022-11-05T00:00:00","guid":{"rendered":"https:\/\/ylu6kzueag.wpdns.site\/news\/six-methods-of-reducing-grounding-resistance\/"},"modified":"2022-11-05T00:00:00","modified_gmt":"2022-11-05T00:00:00","slug":"six-methods-of-reducing-grounding-resistance","status":"publish","type":"post","link":"https:\/\/www.yojiuelec.com\/hi\/news\/six-methods-of-reducing-grounding-resistance\/","title":{"rendered":"Six Methods of Reducing Grounding Resistance"},"content":{"rendered":"<p><span>In sandy, rock pan and other soils with large earth resistivity, in order to meet the requirements of low <a href=\"\/hi\/%e0%a4%85%e0%a4%b0%e0%a5%8d%e0%a4%a5%e0%a4%bf%e0%a4%82%e0%a4%97-%e0%a4%b8%e0%a4%bf%e0%a4%b8%e0%a5%8d%e0%a4%9f%e0%a4%ae\/\">grounding<\/a> resistance,\u00a0a grounding<\/span><\/p>\n<p><span> grid composed of multiple grounding bodies in parallel is often used. However, sometimes a lot of steel materials\u00a0are needed and the <\/span><\/p>\n<p><span>grounding area is very large, so it is often difficult to achieve the required grounding resistance. At this time,we can try to reduce the earth<\/span><\/p>\n<p><span> resistivity of the soil near the grounding body, and also achieve the goal of reducing the grounding resistance.<\/span><\/p>\n<p><span><a href=\"\/hi\/assets\/article-restoration\/fdf878b52e850e86468ee5ab.webp\/\"><img alt=\"Grounding\" decoding=\"async\" height=\"331\" loading=\"lazy\" src=\"\/assets\/article-restoration\/fdf878b52e850e86468ee5ab.webp\" width=\"353\"\/><\/a> <a href=\"\/hi\/assets\/article-restoration\/d35ad0c303c6f38fc9d83763.webp\/\"><img alt=\"Grounding\" decoding=\"async\" height=\"307\" loading=\"lazy\" src=\"\/assets\/article-restoration\/d35ad0c303c6f38fc9d83763.webp\" width=\"526\"\/><\/a><\/span><\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<p><span><strong>1. Use low resistivity soil (i.e. soil replacement method)<\/strong><\/span><\/p>\n<p><span>Clay, peat, black soil and sandy clay are used to replace the original soil with high electrical resistance coefficient, and coke and charcoal <\/span><\/p>\n<p><span>can also be used if necessary. The replacement range is 1~2m around the grounding electrode and 1\/3 of the grounding electrode at the <\/span><\/p>\n<p><span>near ground side. After such treatment, the grounding resistance can be reduced to about 3\/5 of the original value.<\/span><\/p>\n<p>\u00a0<\/p>\n<p><span><strong>2. Artificial treatment such as adding salt<\/strong><\/span><\/p>\n<p><span>Add salt, coal cinder, carbon dust, furnace ash, coke ash, etc. to the soil around the grounding body to improve the conductivity of the soil. <\/span><\/p>\n<p><span>The most commonly used is salt. Because salt has a good effect on improving the soil resistance coefficient, it is less subject to seasonal<\/span><\/p>\n<p><span> changes,<\/span><span>and the price is low. The treatment method is to dig a pit with a diameter of about 0.5~1.0m around each grounding body, and fill<\/span><\/p>\n<p><span> salt and soil\u00a0<\/span><span>into the pit layer by layer. Generally, the thickness of salt layer is about 1cm, and the thickness of soil is about 10cm. Each layer<\/span><\/p>\n<p><span> of salt should be\u00a0<\/span><span>wetted with water. The salt consumption of a tubular grounding body is about 30-40kg; This method can reduce the grounding<\/span><\/p>\n<p><span> resistance to the\u00a0<\/span><span>original (1\/6-1\/8) for sandy soil and (2\/5-1\/3) for sandy clay. If you add about 10kg charcoal, the effect will be better. As charcoal <\/span><\/p>\n<p><span>is a solid\u00a0<\/span><span>conductor, it will not be dissolved, penetrated and corroded, so its effective time is long. For flat steel, round steel and other parallel <\/span><\/p>\n<p><span>grounding\u00a0<\/span><span>bodies, better results can be obtained by using the above methods. However, this method also has disadvantages, such as little effect <\/span><\/p>\n<p><span>on rocks and\u00a0<\/span><span>soil with more rocks; The stability of grounding body is reduced; It will accelerate the corrosion of grounding body; The ground <\/span><\/p>\n<p><span>resistance will\u00a0<\/span><span>slowly increase due to the gradual melting and loss of salt. Therefore, it needs to be treated once about 2 years after manual treatment.<\/span><\/p>\n<p>\u00a0<\/p>\n<p><span><strong>3. External <a href=\"\/hi\/%e0%a4%85%e0%a4%b0%e0%a5%8d%e0%a4%a5%e0%a4%bf%e0%a4%82%e0%a4%97-%e0%a4%b8%e0%a4%bf%e0%a4%b8%e0%a5%8d%e0%a4%9f%e0%a4%ae\/\">grounding<\/a><\/strong><\/span><\/p>\n<p><span>Especially in hilly areas, when the grounding resistance value is required to be small and difficult to reach in situ, if there is water source or<\/span><\/p>\n<p><span> soil with low resistance coefficient nearby, the place can be used to make grounding electrodes or lay underwater grounding grid. Then, use <\/span><\/p>\n<p><span>the grounding wire (such as flat steel strip) to connect it as the external grounding. However, it should be noted that the external grounding <\/span><\/p>\n<p><span>device should avoid the pedestrian channel to prevent electric shock caused by step voltage; When crossing the highway, the buried depth of <\/span><\/p>\n<p><span>the external lead shall be no less than 0.8m.<\/span><\/p>\n<p>\u00a0<\/p>\n<p><span><strong>4. Conductive concrete<\/strong><\/span><\/p>\n<p><span>Carbon fiber is mixed into cement to be used as grounding electrode. For example, about 100kg of carbon fiber is added into 1m3 of cement<\/span><\/p>\n<p><span> to make a hemispherical (1m in diameter) grounding electrode. Through measurement, its power frequency grounding resistance (compared <\/span><\/p>\n<p><span>with ordinary concrete) can generally be reduced by about 30%. This method is often used for lightning protection and grounding devices. In <\/span><\/p>\n<p><span>order to further reduce the impulse grounding resistance, the needle shaped grounding electrode can also be embedded in the conductive<\/span><\/p>\n<p><span> concrete at the same time, so that the discharge corona can continuously ground wave and carbon fiber from the needle tip, which has an <\/span><\/p>\n<p><span>obvious effect on reducing the impulse grounding resistance.<\/span><\/p>\n<p>\u00a0<\/p>\n<p><span><strong>5. Chemical treatment with drag reducing agent<\/strong><\/span><\/p>\n<p><span>The resistance reducing agent using carbon powder and quicklime as the main raw materials can be used in the soil for a long time and will <\/span><\/p>\n<p><span>not be lost due to the groundwater because it does not contain dielectric, so it can obtain a long-term pollution-free and stable low grounding<\/span><\/p>\n<p><span> resistance (about 1\/2 lower than that before using the resistance reducing agent to treat the soil). For hard rock plate zone, the method of <\/span><\/p>\n<p><span>burying grounding wire and resistance reducing agent is quite effective, and its grounding resistance can be reduced by about 40% compared<\/span><\/p>\n<p><span> with that of burying only grounding wire. In addition, this method can achieve good results as long as powdery resistance reducing agent or <\/span><\/p>\n<p><span>long-acting resistance reducing agent is sprinkled in the trench excavated and laid with grounding wire, and then the old soil is backfilled.<\/span><\/p>\n<p>\u00a0<\/p>\n<p><span><strong>6. Borehole deep burial method<\/strong><\/span><\/p>\n<p><span>This method has been reported abroad for a long time, and has achieved good results in practical use. In recent years, China has also <\/span><\/p>\n<p><span>begun to use this new method of resistance reduction. The length of the vertical grounding body used in this method is generally 5~10m<\/span><\/p>\n<p><span> depending on the geological conditions. If it is longer, the effect will not be obvious and the construction will be difficult. The grounding <\/span><\/p>\n<p><span>body usually adopts \u03a6 20~75mm round steel. The influence of round steel with different diameters on the grounding resistance is very<\/span><\/p>\n<p><span> small. This method is applicable to crowded buildings or narrow areas where grounding grids are laid. In these situations, it is difficult to<\/span><\/p>\n<p><span> find the proper position of buried grounding electrode with traditional methods, and the safe distance cannot be guaranteed. Although the<\/span><\/p>\n<p><span> safety can be ensured by covering the grounding body with asphalt insulating layer, the construction workload and installation cost are<\/span><\/p>\n<p><span> increased. The deep burial method is the most effective method for sandy soil, because most of its sandy layers are in the surface layer <\/span><\/p>\n<p><span>within 3m, while the soil resistivity in the deep layer is low. In addition, the method is also applicable to rocky rock plate areas.<\/span><\/p>\n<p><span>\u00a0<\/span><\/p>\n<p><span>During construction \u03a6 Small manual auger or drilling machine with a diameter of 50mm and above. Buried in the drilled hole \u03a6 20~75mm <\/span><\/p>\n<p><span>round steel grounding body, and then filled with carbon mortar (mixed with carbon fiber water slurry) or slurry. Finally, several grounding<\/span><\/p>\n<p><span> bodies with the same treatment are connected in parallel to form a complete grounding body. The grounding body constructed by this method <\/span><\/p>\n<p><span>is less affected by seasons and can obtain stable grounding resistance. At the same time, due to the deep burial, the step voltage can also be <\/span><\/p>\n<p><span>significantly reduced, which is very beneficial to the protection of personal safety. This method is convenient in construction, low in cost and<\/span><\/p>\n<p><span> remarkable in effect, which will be popularized and applied.\u00a0<\/span><\/p>\n<p><a href=\"\/hi\/assets\/article-restoration\/9de1dbb8c683f6f31c47f39b.webp\/\"><img alt=\"https:\/\/www.yojiuelec.com\/earthing-system\/\" decoding=\"async\" height=\"800\" loading=\"lazy\" src=\"\/assets\/article-restoration\/9de1dbb8c683f6f31c47f39b.webp\" width=\"800\"\/><\/a><\/p>\n<p><a href=\"\/hi\/assets\/article-restoration\/153c664861cba403059a6730.jpg\/\"><img alt=\"R-C\" decoding=\"async\" height=\"750\" loading=\"lazy\" src=\"\/assets\/article-restoration\/153c664861cba403059a6730.jpg\" width=\"750\"\/><\/a><\/p>\n<div><\/div>","protected":false},"excerpt":{"rendered":"<p>In sandy, rock pan and other soils with large earth resistivity, in order to meet the requirements of low grounding resistance,\u00a0a grounding grid composed of multiple grounding bodies in parallel is often used. However, sometimes a lot of st<\/p>","protected":false},"author":1,"featured_media":1233,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[27],"tags":[],"class_list":["post-1302","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/posts\/1302","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/comments?post=1302"}],"version-history":[{"count":0,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/posts\/1302\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/media\/1233"}],"wp:attachment":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/media?parent=1302"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/categories?post=1302"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/tags?post=1302"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}