{"id":1447,"date":"2022-10-12T00:00:00","date_gmt":"2022-10-12T00:00:00","guid":{"rendered":"https:\/\/ylu6kzueag.wpdns.site\/news\/fs-composite-cross-arm-insulator\/"},"modified":"2022-10-12T00:00:00","modified_gmt":"2022-10-12T00:00:00","slug":"fs-composite-cross-arm-insulator","status":"publish","type":"post","link":"https:\/\/www.yojiuelec.com\/hi\/news\/fs-composite-cross-arm-insulator\/","title":{"rendered":"FS Composite Cross Arm Insulator"},"content":{"rendered":"<p><a href=\"\/hi\/composite-cross-arm-insulator-product\/\">FS composite cross arm insulator<\/a> adopts hardware made of special steel, and the end of hardware adopts labyrinth design principle,<\/p>\n<p>with multi-layer protection and good sealing performance, which solves the most critical problem of insulator interface electrical<\/p>\n<p>breakdown. The most advanced computer controlled coaxial constant pressure crimping process in the world is adopted for the<\/p>\n<p>connection between the fittings and the mandrel, and a fully automatic acoustic emission flaw detection system is equipped to ensure<\/p>\n<p>the reliability and stability of the connection between the fittings and the mandrel. ERC high-temperature acid resistant rod is used<\/p>\n<p>as the core rod, and the interface between the core rod and silicone rubber is coated with a special coupling agent. The umbrella cover<\/p>\n<p>adopts the one-time overall molding process under high temperature and pressure, and the two-stage vulcanization process monitored<\/p>\n<p>by the computer extends the service life of the product.<\/p>\n<p>1\u3001 Service conditions:<\/p>\n<p>\uff081\uff09. The ambient temperature is \u2013 40 \u2103~+40 \u2103, and the altitude is not more than 1500m.<\/p>\n<p>\uff082\uff09. The frequency of AC power supply shall not exceed 100H, and the maximum wind speed shall not exceed 35m\/s.<\/p>\n<p>\uff083\uff09. The earthquake intensity shall not exceed magnitude 8.<\/p>\n<p>2\u3001 Features:<\/p>\n<p>\uff081\uff09. Small size, light weight, convenient for transportation and installation.<\/p>\n<p>\uff082\uff09. High mechanical strength, reliable structure, stable performance, and large margin for safe operation provide guarantee for the<\/p>\n<p>line and safe operation.<\/p>\n<p>\uff083\uff09. The electrical function is superior. The silicone rubber umbrella can have good hydrophobicity and mobility, good pollution<\/p>\n<p>resistance, strong pollution flashover resistance, safe operation in heavily polluted areas, and no manual cleaning is required. Zero<\/p>\n<p>value maintenance can be avoided.<\/p>\n<p>\uff084\uff09. It has the characteristics of acid resistance, alkali resistance, heat aging resistance and electricity resistance, good sealing<\/p>\n<p>performance, and can ensure that its internal insulation is not affected by moisture.<\/p>\n<p>\uff085\uff09. Good brittleness resistance, strong shock resistance, and no brittle fracture accident.<\/p>\n<p>\uff086\uff09. It is interchangeable with porcelain and other insulators.<\/p>\n<p>\u00a0<\/p>\n<p><a href=\"\/hi\/%e0%a4%b2%e0%a4%be%e0%a4%87%e0%a4%9f%e0%a4%a8%e0%a4%bf%e0%a4%82%e0%a4%97-%e0%a4%86%e0%a4%b0%e0%a5%8d%e0%a4%b8%e0%a5%8d%e0%a4%9f%e0%a4%b0-%e0%a4%ab%e0%a5%8d%e0%a4%af%e0%a5%82%e0%a4%9c-%e0%a4%95\/\"><strong>Product type of composite cross arm insulator<\/strong><\/a><\/p>\n<p>: FXBW \u2014 rod suspension insulator<\/p>\n<p>: FPQ \u2014- Composite pin insulator<\/p>\n<p>: FZSW \u2014- Composite post insulator<\/p>\n<p>: FS \u2014\u2014 Composite cross arm insulator<\/p>\n<p>: FCGW \u2013 composite dry wall bushing<\/p>\n<p>: FQE (X) \u2013 Composite Insulators for Electrified Railways<\/p>\n<p>: FQJ \u2014\u2014 Roof composite insulator for electrified road<\/p>\n<p><a href=\"\/hi\/assets\/article-restoration\/e56af4645c3608168b17b889.jpg\/\"><img alt=\"Electrical grounding\" decoding=\"async\" height=\"314\" loading=\"lazy\" src=\"\/assets\/article-restoration\/e56af4645c3608168b17b889.jpg\" width=\"500\"\/><\/a><\/p>\n<p><strong>Product description of composite cross arm insulator<\/strong><\/p>\n<p>\u25c6 F represents composite; P represents needle type; Q represents antifouling type<\/p>\n<p>\u25c6 4 stands for antifouling grade<\/p>\n<p>\u25c6&lt;10\/3&gt;Rated voltage (kv)\/rated bending load (kN)<\/p>\n<p>\u25c6 T-iron cross arm; L-FRP cross arm; M-Wooden cross arm<\/p>\n<p>\u25c6&lt;20&gt;steel foot diameter (mm)<\/p>\n<p>\u25c6 Color: dark red is omitted; H-gray; G \u2013 green;<\/p>\n<p>\u00a0<\/p>\n<p><strong>What is cross arm insulator called line insulator?<\/strong><\/p>\n<p>Insulators used for overhead lines are called line insulators The insulators used to support bus bars or disconnectors in power<\/p>\n<p>stations are called station post insulators. The role of bushing is to connect the internal live terminal of electrical equipment<\/p>\n<p>with the external system or connect the indoor live terminal with the outdoor system. Porcelain sleeve type power station<\/p>\n<p>insulator is used as the container and insulating sheath of electric instrument transformer, current transformer, lightning<\/p>\n<p>arrester and other equipment. Another type of insulator is the cable end, through which the cable is connected to the overhead line.<\/p>\n<div><\/div>","protected":false},"excerpt":{"rendered":"<p>FS composite cross arm insulator adopts hardware made of special steel, and the end of hardware adopts labyrinth design principle, with multi-layer protection and good sealing performance, which solves the most critical problem of insulator<\/p>","protected":false},"author":1,"featured_media":897,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[27],"tags":[],"class_list":["post-1447","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/posts\/1447","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/comments?post=1447"}],"version-history":[{"count":0,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/posts\/1447\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/media\/897"}],"wp:attachment":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/media?parent=1447"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/categories?post=1447"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/tags?post=1447"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}