{"id":1470,"date":"2022-03-14T00:00:00","date_gmt":"2022-03-14T00:00:00","guid":{"rendered":"https:\/\/ylu6kzueag.wpdns.site\/news\/how-to-ensure-the-cable-clamp-compatibility\/"},"modified":"2022-03-14T00:00:00","modified_gmt":"2022-03-14T00:00:00","slug":"how-to-ensure-the-cable-clamp-compatibility","status":"publish","type":"post","link":"https:\/\/www.yojiuelec.com\/hi\/news\/how-to-ensure-the-cable-clamp-compatibility\/","title":{"rendered":"How to ensure the cable \u2013 clamp compatibility ?"},"content":{"rendered":"<p><span>To develop reliable and future-proof telecom networks it is essential that the selected anchoring and\u00a0<\/span><span>suspension <\/span><\/p>\n<p><span>solutions to be qualified for the type of network on which they will be installed. The mechanical connection <\/span><\/p>\n<p><span>between a clamp and the cable to roll-out is an important issue for overhead networks. A suitable aerial cable <\/span><\/p>\n<p><span>clamp must be able to ensure an effective cable grip, without damaging the sheath of the cable or having any <\/span><\/p>\n<p><span>impact whatsoever on the quality of the transmitted optical signal. To ensure the compatibility between an anchor<\/span><\/p>\n<p><span> \u092f\u093e <a href=\"\/hi\/adss-%e0%a4%aa%e0%a5%8b%e0%a4%b2-%e0%a4%a1%e0%a5%8d%e0%a4%b0%e0%a5%89%e0%a4%aa-%e0%a4%a1%e0%a5%87%e0%a4%a1-%e0%a4%8f%e0%a4%82%e0%a4%a1-%e0%a4%8f%e0%a4%82%e0%a4%95%e0%a4%b0%e0%a4%bf%e0%a4%82%e0%a4%97\/\">\u0938\u0938\u094d\u092a\u0947\u0902\u0936\u0928 \u0915\u094d\u0932\u0948\u0902\u092a<\/a> and the outdoor cable, three main criteria are to be considered:<\/span><\/p>\n<p><span>\u2606 the cable\u2019s structure<\/span><\/p>\n<p><span>\u2606 the cable\u2019s diametere<\/span><\/p>\n<p><span>\u2606 the span length of the network to roll-out: the longer the span, the longer the clamp\u2019s bail. This will enable <\/span><\/p>\n<p><span>to avoid any contact between the clamp\u2019s bail and other elements and most importantly, to respect the cable\u2019s <\/span><\/p>\n<p><span>bend radius when this one is used in configurations consisting of creating a small loop above or underneath <\/span><\/p>\n<p><span>the pole\u2019s top.<\/span><br \/>\n<span>For telecommunications feeder networks, characterised by greater span lengths, helical dead-ends offer a better <\/span><\/p>\n<p><span>cable grip thanks to their large contact surface with the cable.<\/span><\/p>\n<p><span>The compatibility between dead-ending solutions and cables to deploy is checked by carrying out the following <\/span><\/p>\n<p><span>qualification tests:<\/span><\/p>\n<p><span>\u2606 Tensile test at the short-term tensile load of the cable (Maximum Allowable Tension) according to EN 60794-1-2 <\/span><\/p>\n<p><span>s<\/span><span>tandard \u2013 modified Method E1, involving a couple of anchoring devices on a cable length greater than 1 meter. <\/span><\/p>\n<p><span>The compatibility between the telecom anchor clamp and the aerial cable is established when there is no slippage <\/span><\/p>\n<p><span>of the cable inside the anchoring clamps, no deterioration of the cable, nor deterioration of the signal (attenuation <\/span><\/p>\n<p><span>less than 0.1dB) .<\/span><br \/>\n<span>\u2606 Galopping test for anchor clamps according to EN 60794-1-2 standard \u2013 Method E1. This consists into applying 10 <\/span><\/p>\n<p><span>undulations to cables with a smaller or equal diameter to 6mm (drops), 3 undulations to cables with a greater diameter <\/span><\/p>\n<p><span>than 6 mm (distribution and feeder cables) and a measurement of optical losses for 300 hours. A test is considered <\/span><\/p>\n<p><span>conclusive when registered optical losses are less than 0.1 dB throughout the test.<\/span><\/p>\n<p><span>Solutions for overhead round self-supporting cable<\/span><\/p>\n<p><span>Depending on the part of the network to be rolled-out, various technological solutions are available for deploying <\/span><\/p>\n<p><span>an overhead telecom network:<\/span><\/p>\n<p><span>For last mile access network: :<\/span><\/p>\n<p><span>There are many different models of anchor clamps for ADSS cable. Conical clamping dead-endings such as those <\/span><\/p>\n<p><span>included in the JYPA range for example are intended for spans up to 70 meters. These anchor clamps are designed <\/span><\/p>\n<p><span>with more enveloping wedges so to fit perfectly onto the cable\u2019s shape and to preserve its functional characteristics <\/span><\/p>\n<p><span>in case of overload. As for wedge clamps, they enable simple or double dead-ending of round drops with small <\/span><\/p>\n<p><span>diameters on poles or walls. Mandrel devices are another fastening solution for aerial drop roll-outs. Especially <\/span><\/p>\n<p><span>designed for the dead-ending of drops with flexible and insulating outer sheath, these anchor clamps present a <\/span><\/p>\n<p><span>mandrel body in which cable can be coiled and self-tighten.<\/span><\/p>\n<p><span>Telenco FTTH drop clamps<\/span><\/p>\n<p><span>For distribution network:<\/span><\/p>\n<p><span>Anchor clamps included in the <a href=\"\/hi\/adss-%e0%a4%aa%e0%a5%8b%e0%a4%b2-%e0%a4%a1%e0%a5%8d%e0%a4%b0%e0%a5%89%e0%a4%aa-%e0%a4%a1%e0%a5%87%e0%a4%a1-%e0%a4%8f%e0%a4%82%e0%a4%a1-%e0%a4%8f%e0%a4%82%e0%a4%95%e0%a4%b0%e0%a4%bf%e0%a4%82%e0%a4%97\/\">JYPA ADSS<\/a> range are overhead cable fastening solutions enabling to start, realise<\/span><\/p>\n<p><span> dead-ending applications all along and to terminate telecom distribution networks where spans do not exceed 90 <\/span><\/p>\n<p><span>meters. Offering an effective cable grip, JYPA ADSS clamps do not exert any bending radius stress on the cable. <\/span><\/p>\n<p><span>Another solution for effectively anchoring round cables on distribution networks is to opt for helical dead-ends using <\/span><\/p>\n<p><span>the preformed technology. GSDE spirals install only on telecommunications networks, where spans do not exceed <\/span><\/p>\n<p><span>90 meters.<\/span><\/p>\n<p><span>For feeder network:<\/span><\/p>\n<p><span>For greater spans, such as for those commonly met on feeder networks, dead-ending applications must be performed <\/span><\/p>\n<p><span>with fastening devices engineered to resist to higher tensile strengths. Designed with armor rods, helical dead-ends <\/span><\/p>\n<p><span>from JYPA range preserve telecom cables deployed on spans up to 180 meters from bending, compression or abrasion.<\/span><\/p>\n<p><a href=\"\/hi\/assets\/article-restoration\/3d94abd0904a079e362394b3.webp\/\"><img alt=\"YJPAP2000(2)\" decoding=\"async\" height=\"800\" loading=\"lazy\" src=\"\/assets\/article-restoration\/3d94abd0904a079e362394b3.webp\" width=\"800\"\/><\/a><\/p>\n<p>\u00a0<\/p>\n<p><a href=\"\/hi\/assets\/article-restoration\/28ea42c2977eaee0251afc75.webp\/\"><img alt=\"Cable Clamps YJPAP Series (2)\" decoding=\"async\" height=\"723\" loading=\"lazy\" src=\"\/assets\/article-restoration\/28ea42c2977eaee0251afc75.webp\" width=\"1241\"\/><\/a><\/p>\n<div><\/div>","protected":false},"excerpt":{"rendered":"<p>To develop reliable and future-proof telecom networks it is essential that the selected anchoring and suspension solutions to be qualified for the type of network on which they will be installed. The mechanical connection between a clamp an<\/p>","protected":false},"author":1,"featured_media":1198,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[27],"tags":[],"class_list":["post-1470","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/posts\/1470","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/comments?post=1470"}],"version-history":[{"count":0,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/posts\/1470\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/media\/1198"}],"wp:attachment":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/media?parent=1470"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/categories?post=1470"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/tags?post=1470"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}