{"id":1556,"date":"2022-10-17T00:00:00","date_gmt":"2022-10-17T00:00:00","guid":{"rendered":"https:\/\/ylu6kzueag.wpdns.site\/news\/technical-development-of-uhv-ac-transmission-and-transformation-equipment-uhv-series-compensation-device\/"},"modified":"2022-10-17T00:00:00","modified_gmt":"2022-10-17T00:00:00","slug":"technical-development-of-uhv-ac-transmission-and-transformation-equipment-uhv-series-compensation-device","status":"publish","type":"post","link":"https:\/\/www.yojiuelec.com\/hi\/news\/technical-development-of-uhv-ac-transmission-and-transformation-equipment-uhv-series-compensation-device\/","title":{"rendered":"Technical Development of UHV AC Transmission and Transformation Equipment \u2014 UHV Series Compensation Device"},"content":{"rendered":"<p>Technical Development of UHV AC Transmission and Transformation Equipment<\/p>\n<p>UHV series compensation device<\/p>\n<p>For large-scale construction of ultra-high voltage projects, core equipment is the key.<\/p>\n<p>In order to promote the further development of UHV AC transmission technology, the latest technical development of\u00a0key equipment<\/p>\n<p>such as UHV AC transformer, gas insulated metal enclosed switchgear (GIS), series compensation device\u00a0and lightning arrester is<\/p>\n<p>summarized and prospected.<\/p>\n<p><strong>The results show that:<\/strong><\/p>\n<p>The allowable value of electric field strength when the partial discharge probability of UHV transformer is 1 \u2030 shall be\u00a0selected as the<\/p>\n<p>allowable field strength;<\/p>\n<p>Magnetic leakage control measures such as magnetic shielding at the end of the body, electrical shielding of the oil tank,magnetic shielding<\/p>\n<p>of the oil tank, and non magnetic conducting steel plate can effectively reduce the magnetic leakage\u00a0and temperature rise of 1500 MVA<\/p>\n<p>large capacity UHV transformer;<\/p>\n<p>The breaking capacity of the UHV circuit breaker can reach 63kA. The synthetic test circuit based on the \u201cthree circuit\u00a0method\u201d can break<\/p>\n<p>through the limit of the test equipment and complete the breaking test of the 1100kV circuit breaker;<\/p>\n<p>It is clear that the amplitude and frequency of VFTO are limited by installing damping resistors on the static contact side\u00a0of \u201cvertical\u201d<\/p>\n<p>disconnectors;<\/p>\n<p>From the point of view of continuous operation voltage, it is safe to reduce the rated voltage of UHV arrester to 780kV.<\/p>\n<p>The future UHV AC power transmission and transformation equipment should be deeply studied in terms of high reliability,large capacity,<\/p>\n<p>new working principle and performance parameter optimization.<\/p>\n<p>UHV AC transformer, switchgear, series compensation device and lightning arrester are the main core equipment of UHV\u00a0AC transmission<\/p>\n<p>project. This time, we will focus on sorting out and summarizing the latest technological development of\u00a0these four types of equipment.<\/p>\n<p>\u00a0<\/p>\n<p>Development of UHV series compensation device<\/p>\n<p>The UHV series compensation device mainly solves the following problems: the influence of the application of series\u00a0compensation on<\/p>\n<p>the system characteristics, the optimization of the key technical parameters of the series compensation,the strong anti electromagnetic<\/p>\n<p>interference capability of the control, protection and measurement system, the design and\u00a0protection of the super capacitor bank, the<\/p>\n<p>flow capacity and operation reliability of the series compensation spark gap,the pressure release capacity and current sharing performance<\/p>\n<p>of the voltage limiter, the quick opening and closing capacity\u00a0of the bypass switch, the damping device, the fiber column The structure<\/p>\n<p>design of current transformer and other key\u00a0technical issues. Under the conditions of ultra-high voltage, ultra-high current and ultra-high<\/p>\n<p>capacity, the problem that a\u00a0number of key technical indicators of the series compensation main equipment reach the performance limit<\/p>\n<p>has been overcome,and the ultra-high voltage series compensation primary equipment has been developed, and all of them have achieved<\/p>\n<p>localization.<\/p>\n<p>\u00a0<\/p>\n<p><strong>Capacitor bank<\/strong><\/p>\n<p>Capacitor bank for series compensation is the basic physical component to realize the series compensation function, and is one\u00a0of the key<\/p>\n<p>equipment of the series compensation device. The number of UHV series compensation capacitors in a single set is\u00a0up to 2500, 3-4 times<\/p>\n<p>that of 500kV series compensation. It is faced with a large number of series parallel connection problems\u00a0of capacitor units under large<\/p>\n<p>compensation capacity. A double H-bridge protection scheme is proposed in China. Combined\u00a0with fancy wiring technology, it solves<\/p>\n<p>the coordination problem between the sensitivity of unbalanced current detection of\u00a0capacitors and the control of injected energy, and also<\/p>\n<p>solves the technical problem of possible burst of series capacitor banks.\u00a0The entity diagram and wiring schematic diagram of series capacitor<\/p>\n<p>banks are shown in Figures 12 and 13.<\/p>\n<p><a href=\"\/hi\/assets\/article-restoration\/c1b3af812f05f70da826d70a.jpg\/\"><img alt=\"Capacitor bank\" decoding=\"async\" height=\"398\" loading=\"lazy\" src=\"\/assets\/article-restoration\/c1b3af812f05f70da826d70a.jpg\" width=\"620\"\/><\/a><\/p>\n<p><strong>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Figures 12\u00a0 Capacitor bank<\/strong><\/p>\n<p><a href=\"\/hi\/assets\/article-restoration\/090aaabcd913ccf12b191a57.webp\/\"><img alt=\"Wiring mode\" decoding=\"async\" height=\"290\" loading=\"lazy\" src=\"\/assets\/article-restoration\/090aaabcd913ccf12b191a57.webp\" width=\"474\"\/><\/a><\/p>\n<p><strong>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Figures 13\u00a0Wiring mode<\/strong><\/p>\n<p><strong>Pressure limiter<\/strong><\/p>\n<p>In view of the extremely demanding reliability requirements of UHV series compensation, the method of resistor chip\u00a0matching is specially<\/p>\n<p>optimized, and the shunt coefficient between columns is reduced from 1.10 to 1.03 after nearly 100\u00a0resistor chip columns of each phase<\/p>\n<p>voltage limiter are connected in parallel (each resistor chip column is connected in\u00a0series by 30 resistors). The specially designed pressure<\/p>\n<p>release structure is adopted, and the pressure release capacity\u00a0reaches 63kA\/0.2s under the condition that the porcelain jacket pressure<\/p>\n<p>limiter unit is 2.2m high and there is no arc\u00a0separator inside.<\/p>\n<p>\u00a0<\/p>\n<p><strong>Spark gap<\/strong><\/p>\n<p>The rated voltage of the spark gap for UHV series compensation reaches 120kV, which is much higher than 80kV of the\u00a0spark gap for UHV<\/p>\n<p>series compensation; The current carrying capacity reaches 63kA\/0.5s (peak value 170kA), 2.5 times\u00a0that of the ultra-high voltage gap. The<\/p>\n<p>developed spark gap has such performances as accurate, controllable and stable\u00a0trigger discharge voltage, sufficient fault current carrying<\/p>\n<p>capacity (63kA, 0.5s), hundreds of microseconds trigger\u00a0discharge delay, fast recovery capability of main insulation (after passing 50kA\/60ms<\/p>\n<p>current, the recovery voltage per\u00a0unit value reaches 2.17 at an interval of 650ms), strong electromagnetic interference resistance, etc.<\/p>\n<p>\u00a0<\/p>\n<p><strong>Series compensation platform<\/strong><\/p>\n<p>A compact, heavy load, high seismic grade UHV series compensation platform has been designed, forming the unique\u00a0international UHV<\/p>\n<p>series compensation true type test and research capability; The three-dimensional mechanical and\u00a0field strength analysis model of complex<\/p>\n<p>multi equipment is established, and the compact layout and support scheme\u00a0of three section bus type platform equipment with integrated<\/p>\n<p>and large enclosure structure is proposed, which solves\u00a0the problems of anti-seismic, insulation coordination and electromagnetic environment<\/p>\n<p>control of overweight platform\u00a0(200t); The UHV series compensation true type test platform has been built, which has formed the large-scale<\/p>\n<p>external\u00a0insulation coordination, corona and space field strength, electromagnetic compatibility of weak current equipment on\u00a0the platform<\/p>\n<p>and other test capabilities of the series compensation platform, filling the blank of UHV series compensation\u00a0test research.<\/p>\n<p>\u00a0<\/p>\n<p><strong>Bypass switch and bypass disconnector<\/strong><\/p>\n<p>A large capacity arc extinguishing chamber and a high-speed operating mechanism were developed, which solved the\u00a0problems of guidance<\/p>\n<p>and mechanical strength of 10m ultra long insulated pull rod under high-speed action. The first\u00a0SF6 porcelain column type bypass switch<\/p>\n<p>with T-shaped structure was developed, with a rated current of 6300A, a closing\u00a0time of \u2264 30ms, and a mechanical life of 10000 times;<\/p>\n<p>The method of adding auxiliary vacuum circuit breaker to the main\u00a0contact and switching current by the main pole is proposed. The first<\/p>\n<p>open type bypass disconnector is developed, and the\u00a0switching current switching capacity is greatly improved to 7kV\/6300A.<\/p>\n<p>\u00a0<\/p>\n<p><strong>Electromagnetic compatibility of weak current equipment on the platform<\/strong><\/p>\n<p>The technical problems such as transient overvoltage control on UHV series compensation platform and electromagnetic\u00a0compatibility of<\/p>\n<p>weak current equipment under high potential and strong interference have been overcome, and the series\u00a0compensation platform<\/p>\n<p>measurement system and spark gap trigger control box with extremely strong anti electromagnetic\u00a0interference capability have been<\/p>\n<p>developed. Figure 14 is the field diagram of UHV series compensation device.<\/p>\n<p>\u00a0<\/p>\n<p>The international first set of UHV fixed series compensation device independently developed by China Electric Power Research\u00a0Institute<\/p>\n<p>has been successfully put into operation in the expansion project of UHV AC test demonstration project. The rated\u00a0current of the device<\/p>\n<p>reaches 5080A, and the rated capacity reaches 1500MVA (reactive power). The main technical indicators\u00a0rank first in the world. The<\/p>\n<p>transmission capacity of the UHV test demonstration project has been increased by 1 million kW.\u00a0The goal of stable transmission of 5<\/p>\n<p>million kW by single circuit UHV lines has been achieved. So far, safe, stable and reliable\u00a0operation has been maintained.<\/p>\n<p><a href=\"\/hi\/assets\/article-restoration\/69c12070f401128ec8bb9e00.webp\/\"><img alt=\"1000KV UHV series compensation device\" decoding=\"async\" height=\"412\" loading=\"lazy\" src=\"\/assets\/article-restoration\/69c12070f401128ec8bb9e00.webp\" width=\"594\"\/><\/a><\/p>\n<p><strong>Figure 14\u00a0 1000KV UHV Series Compensation Device<\/strong><\/p>\n<div><\/div>","protected":false},"excerpt":{"rendered":"<p>Technical Development of UHV AC Transmission and Transformation Equipment UHV series compensation device For large-scale construction of ultra-high voltage projects, core equipment is the key. In order to promote the further development of <\/p>","protected":false},"author":1,"featured_media":1225,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[26],"tags":[],"class_list":["post-1556","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news"],"_links":{"self":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/posts\/1556","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/comments?post=1556"}],"version-history":[{"count":0,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/posts\/1556\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/media\/1225"}],"wp:attachment":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/media?parent=1556"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/categories?post=1556"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/tags?post=1556"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}