{"id":214,"date":"2026-11-11T03:22:10","date_gmt":"2026-11-11T03:22:10","guid":{"rendered":"https:\/\/ylu6kzueag.wpdns.site\/product\/nll-type-electric-overhead-wire-cable-clamp-suspension-strain-tension-clamps\/"},"modified":"2026-11-11T03:22:10","modified_gmt":"2026-11-11T03:22:10","slug":"nll-type-electric-overhead-wire-cable-clamp-suspension-strain-tension-clamps","status":"publish","type":"product","link":"https:\/\/www.yojiuelec.com\/hi\/nll-type-electric-overhead-wire-cable-clamp-suspension-strain-tension-clamps-product\/","title":{"rendered":"NLL \u0913\u0935\u0930\u0939\u0947\u0921 \u0932\u093e\u0907\u0928 \u091f\u0947\u0902\u0936\u0928 \u0915\u094d\u0932\u0948\u0902\u092a\u094d\u0938"},"content":{"rendered":"<section aria-labelledby=\"overview-title\" class=\"product-overview\" id=\"product-overview\">\n<div class=\"section-wrap\">\n<h2 id=\"overview-title\">\u0905\u0935\u0932\u094b\u0915\u0928\u0964<\/h2>\n<div class=\"product-description-block\">\n<p class=\"product-description\">Fasten overhead conductors and ground wires to tower arms or substation structures through insulators and link fittings. The NLL series uses a bolted aluminium alloy strain-clamp design for AAC and ACSR conductors, with optional aluminium tape or preformed armour rods for protection.<\/p>\n<p class=\"product-full-name\">NLL \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0940 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0913\u0935\u0930\u0939\u0947\u0921 \u0935\u093e\u092f\u0930 \u0915\u0947\u092c\u0932 \u0915\u094d\u0932\u0948\u0902\u092a \u0938\u0938\u094d\u092a\u0947\u0902\u0936\u0928 \u0938\u094d\u091f\u094d\u0930\u0947\u0928 \u091f\u0947\u0902\u0936\u0928 \u0915\u094d\u0932\u0948\u0902\u092a\u094d\u0938<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section aria-labelledby=\"specifications-title\" class=\"product-specifications\" id=\"product-specifications\">\n<div class=\"section-wrap product-spec-layout\">\n<header>\n<h2 id=\"specifications-title\">\u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u0964<\/h2>\n<p>\u0905\u092a\u0928\u0947 \u0906\u0907\u091f\u092e \u0928\u0902\u092c\u0930 \u0915\u094b \u0928\u0940\u091a\u0947 \u0926\u093f\u090f \u0917\u090f \u0906\u092f\u093e\u092e\u094b\u0902 \u0914\u0930 \u0930\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u0915\u0947 \u0938\u093e\u0925 \u092e\u093f\u0932\u093e\u090f\u0902\u0964<\/p>\n<\/header>\n<div class=\"product-table-stack\">\n<div aria-label=\"\u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\" class=\"product-table-scroll\" role=\"region\" tabindex=\"0\">\n<table>\n<caption class=\"sr-only\">\u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936<\/caption>\n<tbody>\n<tr>\n<th rowspan=\"2\" scope=\"col\">\u092a\u094d\u0930\u0915\u093e\u0930<\/th>\n<th rowspan=\"2\" scope=\"col\">Applicable Conductor(mm)<\/th>\n<th colspan=\"4\" scope=\"col\">\u0906\u092f\u093e\u092e (\u092e\u093f\u092e\u0940)<\/th>\n<th rowspan=\"2\" scope=\"col\">Rated Failure Load(KN)<\/th>\n<\/tr>\n<tr>\n<td>L<\/td>\n<td>I<\/td>\n<td>C<\/td>\n<td>d<\/td>\n<\/tr>\n<tr>\n<td>NLL-1<\/td>\n<td>5.1-11.4<\/td>\n<td>125<\/td>\n<td>110<\/td>\n<td>18<\/td>\n<td>16<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>NLL-2<\/td>\n<td>11.4-16<\/td>\n<td>175<\/td>\n<td>186<\/td>\n<td>20<\/td>\n<td>16<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>NLL-3<\/td>\n<td>14.5-17.5<\/td>\n<td>190<\/td>\n<td>205<\/td>\n<td>22<\/td>\n<td>16<\/td>\n<td>70<\/td>\n<\/tr>\n<tr>\n<td>NLL-4<\/td>\n<td>18-22.4<\/td>\n<td>300<\/td>\n<td>285<\/td>\n<td>30<\/td>\n<td>18<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<td>NLL-5<\/td>\n<td>23-30<\/td>\n<td>445<\/td>\n<td>345<\/td>\n<td>36<\/td>\n<td>24<\/td>\n<td>120<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"<p class=\"product-intro\">Fasten overhead conductors and ground wires to tower arms or substation structures through insulators and link fittings. The NLL series uses a bolted aluminium alloy strain-clamp design for AAC and ACSR conductors, with optional aluminium tape or preformed armour rods for protection.<\/p>\n<ul class=\"product-key-points\">\n<li>Bolted aluminium alloy strain clamp<\/li>\n<li>For AAC and ACSR conductors<\/li>\n<li>Listed conductor diameters: 5.1\u201330 mm<\/li>\n<\/ul>","protected":false},"featured_media":51,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[20],"product_tag":[],"class_list":["post-214","product","type-product","status-publish","has-post-thumbnail","product_cat-overhead-line-fitting","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/product\/214","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/comments?post=214"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/media\/51"}],"wp:attachment":[{"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/media?parent=214"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/product_brand?post=214"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/product_cat?post=214"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.yojiuelec.com\/hi\/wp-json\/wp\/v2\/product_tag?post=214"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}