Good Quality Insulator - Drop Type Fuse Cutout – Yongjiu
Good Quality Insulator - Drop Type Fuse Cutout – Yongjiu Detail:
Drop type fuse cutouts are outdoor high voltage protection facilities. The fuse is installed at high voltage side of transformer or branch line of distribution line to protect transformer or transmission line from short circuit and overload, to break and connect load current.
Fuse cutout consist of insulation bracket and fuse tube, fixed contact is installed at both ends of insulation bracket, moving contact is installed at both ends of fuse tube. Fuse tube consist of two parts, arcing extinguish tube in inner side and epoxy glass tube outside. Tension load fuse cutout increase the flexible auxiliary contact and arcing-extinguish shield to break or connect load current.
Drop type fuse cutout is a low cost line protection, primarily used on remote overhead electrical transmission lines. The visual display of the status of the fuse cutout quickly and accurately helps field inspectors to locate the faulty segment of the overhead transmission line. Upon clearing of the line fault and replacing the fuse link, each of the phases can then be individually switched back into operation using operating poles, which are available in desired lengths.
1、Service condition:
a) The ambient air temperatures: -40 to 40℃
b) The altitude above sea level: 1000m.
c) Wind speed doesn’t exceed 700Pa (not exceed 34m/s)
d) The earthquake intensity doesn’t exceed 8 degrees.
2、The product is not applicable to the following locations:
a) Combustion or explosion risk areas.
b) With severe vibration or shock sites.
c) A conductive, chemical gas and serious pollution, salt fog area.
11-15kV
Item No. |
Rated Voltage (kV) |
Rated Current (A) |
Breaking Current (A) |
Impulse Voltage (BIL) |
Power Frequency Withstand Voltage |
Leakage Distance (MM) |
Weight (KG) |
Dimension (CM) |
YJF-1 |
12 |
100 |
6300 |
110 |
40 |
250 |
6.5 |
40×36 |
YJF-1 |
12 |
200 |
10000 |
110 |
40 |
250 |
6.5 |
11-15kV
Item No. |
Rated Voltage (kV) |
Rated Current (A) |
Breaking Current (A) |
Impulse Voltage (BIL) |
Power Frequency Withstand Voltage |
Leakage Distance (MM) |
Weight (KG) |
Dimension (CM) |
YJF-2 |
15 |
100 |
8000 |
125 |
45 |
320 |
7.5 |
50×36 |
YJF-2 |
15 |
200 |
12500 |
125 |
45 |
320 |
7.5 |
11- 15KV( F)
Item No. |
Rated Voltage (kV) |
Rated Current (A) |
Breaking Current (A) |
Impulse Voltage (BIL) |
Power Frequency Withstand Voltage |
Leakage Distance (MM) |
Weight (KG) |
Dimension (CM) |
YJF2(F)-2 |
15 |
100 |
8000 |
125 |
45 |
320 |
8 |
58×40 |
YJF2(F)-2 |
15 |
200 |
12500 |
125 |
45 |
320 |
8 |
24kV-27kV
Item No. |
Rated Voltage (kV) |
Rated Current (A) |
Breaking Current (A) |
Impulse Voltage (BIL) |
Power Frequency Withstand Voltage |
Leakage Distance (MM) |
Weight (KG) |
Dimension (CM) |
YJF-3 |
24 |
100 |
8000 |
150 |
65 |
530 |
12 |
50×38 |
YJF-3 |
24 |
200 |
12500 |
150 |
65 |
530 |
12 |
Fuse Cutout Series 12-36kV
33kV-36kV
Item No. |
Rated Voltage (kV) |
Rated Current (A) |
Breaking Current (A) |
Impulse Voltage (BIL) |
Power Frequency Withstand Voltage |
Leakage Distance (MM) |
Weight (KG) |
Dimension (CM) |
YJF-4 |
33 |
100 |
8000 |
170 |
70 |
720 |
15 |
64×35 |
YJF-4 |
33 |
200 |
12500 |
170 |
70 |
720 |
15 |
11kV-15kV
Item No. |
Rated Voltage (kV) |
Rated Current (A) |
Breaking Current (A) |
Impulse Voltage (BIL) |
Power Frequency Withstand Voltage |
Leakage Distance (MM) |
Weight (KG) |
Dimension (CM) |
YJF-5 |
12 |
100 |
6300 |
110 |
40 |
250 |
6.5 |
40×36 |
YJF-5 |
12 |
200 |
10000 |
110 |
40 |
250 |
6.5 |
24kV-27kV
Item No. |
Rated Voltage (kV) |
Rated Current (A) |
Breaking Current (A) |
Impulse Voltage (BIL) |
Power Frequency Withstand Voltage |
Leakage Distance (MM) |
Weight (KG) |
Dimension (CM) |
YJF-6 |
24 |
100 |
8000 |
150 |
65 |
540 |
10 |
60×38 |
YJF-6 |
24 |
200 |
12500 |
150 |
65 |
540 |
10 |
11- 15KV
Item No. |
Rated Voltage (kV) |
Rated Current (A) |
Breaking Current (A) |
Impulse Voltage (BIL) |
Power Frequency Withstand Voltage |
Leakage Distance (MM) |
Weight (KG) |
Dimension (CM) |
HYJF-2 |
15 |
100 |
6300 |
110 |
40 |
250 |
6 |
40×36 |
HYJF-2 |
15 |
200 |
10000 |
110 |
40 |
250 |
6 |
Fuse Cutout Series 12-36kV
11- 15KV
Item No. |
Rated Voltage (kV) |
Rated Current (A) |
Breaking Current (A) |
Impulse Voltage (BIL) |
Power Frequency Withstand Voltage |
Leakage Distance (MM) |
Weight (KG) |
Dimension (CM) |
HYJF-2 |
15 |
100 |
6300 |
110 |
40 |
250 |
6 |
40×38×16 |
HYJF-2 |
15 |
200 |
10000 |
110 |
40 |
250 |
6 |
24-27kV
Item No. |
Rated Voltage (kV) |
Rated Current (A) |
Breaking Current (A) |
Impulse Voltage (BIL) |
Power Frequency Withstand Voltage |
Leakage Distance (MM) |
Weight (KG) |
Dimension (CM) |
HYJF-3 |
24 |
100 |
8000 |
150 |
65 |
530 |
7 |
50×38×16 |
HYJF-3 |
24 |
200 |
12500 |
150 |
65 |
530 |
7 |
33-36kV
Item No. |
Rated Voltage (kV) |
Rated Current (A) |
Breaking Current (A) |
Impulse Voltage (BIL) |
Power Frequency Withstand Voltage |
Leakage Distance (MM) |
Weight (KG) |
Dimension (CM) |
HYJF-4 |
33 |
100 |
8000 |
125 |
45 |
320 |
7.5 |
50×38×12.5 |
HYJF-4 |
33 |
200 |
12500 |
125 |
45 |
320 |
7.5 |
24kV-27kV
Item No. |
Rated Voltage (kV) |
Rated Current (A) |
Breaking Current (A) |
Impulse Voltage (BIL) |
Power Frequency Withstand Voltage |
Leakage Distance (MM) |
Weight (KG) |
Dimension (CM) |
HYJF-3 |
24 |
100 |
8000 |
150 |
65 |
540 |
7 |
50×38×16 |
HYJF-3 |
24 |
200 |
12500 |
150 |
65 |
540 |
7 |
33-36kV
Item No. |
Rated Voltage (kV) |
Rated Current (A) |
Breaking Current (A) |
Impulse Voltage (BIL) |
Power Frequency Withstand Voltage |
Leakage Distance (MM) |
Weight (KG) |
Dimension (CM) |
HYJF-4 |
33 |
100 |
8000 |
170 |
70 |
720 |
8 |
64×36 |
HYJF-4 |
33 |
200 |
12500 |
170 |
70 |
720 |
8 |
24kV-27kV
Item No. |
Rated Voltage (kV) |
Rated Current (A) |
Breaking Current (A) |
Impulse Voltage (BIL) |
Power Frequency Withstand Voltage |
Leakage Distance (MM) |
Weight (KG) |
Dimension (CM) |
HYJF-7 |
24 |
100 |
8000 |
150 |
65 |
540 |
10 |
50×36 |
HYJF-7 |
24 |
200 |
10000 |
150 |
65 |
540 |
10 |
33kV-36kV
Item No. |
Rated Voltage (kV) |
Rated Current (A) |
Breaking Current (A) |
Impulse Voltage (BIL) |
Power Frequency Withstand Voltage |
Leakage Distance (MM) |
Weight (KG) |
Dimension (CM) |
HYJF-8 |
33 |
100 |
10000 |
170 |
70 |
720 |
15 |
64×35 |
HYJF-8 |
33 |
200 |
12500 |
170 |
70 |
720 |
15 |
12kV
Item No. |
Rated Voltage (kV) |
Rated Current (A) |
Breaking Current (A) |
Impulse Voltage (BIL) |
Power Frequency Withstand Voltage |
Leakage Distance (MM) |
Weight (KG) |
Dimension (CM) |
RW11 |
12 |
100 |
6300 |
110 |
42 |
260 |
7.5 |
48×32 |
RW11 |
12 |
200 |
8000 |
110 |
42 |
260 |
7.5 |
Q:CAN YOU HELP US IMPROT AND EXPORT?
A:We will have a professional team to serve you.
Q:WHAT’S THE CERTIFICATES DO YOU HAVE?
A:We have certificates of ISO,CE, BV,SGS.
Q:WHAT’S YOUR WARRANTY PERIOD?
A:1 year in general.
Q:CAN YOU DO OEM SERVICE?
A:YES,we can.
Q:WHAT YOU LEAD TIME?
A:Our standard models are in stock ,as for big orders ,it take about 15 days.
Q:CAN YOU PROVIDE FREE SAMPLES?
A:Yes,please contact us to know the sample policy.
Product detail pictures:
Related Product Guide:
abide by the contract", conforms into the market requirement, joins in the market competition by its good quality also as provides a lot more comprehensive and great company for purchasers to let them turn into huge winner. The pursue from the firm, would be the clients' gratification for Good Quality Insulator - Drop Type Fuse Cutout – Yongjiu , The product will supply to all over the world, such as: Lebanon, Palestine, belarus, We are sticking to excellent quality, competitive price and punctual delivery and better service, and sincerely hope to establish long-term good relationships and cooperation with our new and old business partners from all over the world. Sincerely welcome you to join us.
By Ann from Morocco - 2018.08.12 12:27
The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
By Rosalind from Detroit - 2017.09.29 11:19